IR Heater Velit Sol Installation Guide

Velit Sol Installation and App Guide

In case of any signal changes or electrical cuts, the thermostat app may need to be reconnected to your Wi-Fi. To do this, you might need to delete the existing heater from the list and add it again by following the step-by-step guide provided.

icon-infrared-mirrors

Mirror Repulsus Installation Guide

icon-infrared-mirrors

Repulsus Mirror Setup

Clear fitting and setup instructions for installing your Repulsus infrared mirror heater safely and correctly

ES-high-quality-components-whiten
fv26

Website rating

4.9 Royal Infrared Heating reviews

Based on 900+ reviews

Effortless Installation for Maximum Comfort

The Repulsus infrared mirror is designed for straightforward wall installation. Each mirror includes the required mounting hardware and a drilling template to help position the fixing points accurately.

Repulsus can be mounted vertically or horizontally. Because it is a substantial glass product, assistance from another person is recommended during lifting and mounting.

Quick and Simple Wall Mounting

Installation requires four holes to be drilled into a suitable wall. The supplied screws and wall plugs secure the mirror through its pre-fitted rear brackets. Once securely mounted, connect Repulsus to a suitable power socket and operate the LED backlight and infrared heating through the built-in touch sensor.

1. Mounting Position

Choose a suitable wall and select vertical or horizontal mounting.

Keep the panel at least 10 cm from nearby walls or objects and approximately 30 cm above the floor. Never install the Repulsus on a ceiling.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-1-min

2. Mark, Drill the Holes

Attach the drilling template to the wall and mark the four mounting points.

Use ANHQ for the Repulsus 500W or AEHK for the Repulsus 350W, then drill each marked hole using a suitable 8 mm bit.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-2-min

3. Install Wall the Fixings

Insert the supplied wall plugs fully into the four drilled holes.

Fit the screws securely, leaving each screw head approximately 5 mm from the wall so the mirror’s mounting brackets can attach safely and remain supported.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-3-min

4. Hang the Panel

Align the pre-fitted brackets on the back of the mirror with the four screw heads.

Carefully place the mirror onto the screws and ensure that every mounting point is correctly engaged.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-4-min

5. Secure the Mirror

Slide the mirror sideways until the screws move into the locked sections of the mounting brackets.

Check that the mirror is level, stable and securely attached before releasing it.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-5-min

6. Connect the Power

Plug Repulsus into a grounded socket. Tap the sensor for the LED, or press and hold it for infrared heat.

Repulsus cannot be used with plug-in or hardwired thermostats.

.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-6-min

Hardwired Installation

For a clean, cable-free finish, ask a qualified electrician to complete the electrical connection. Repulsus must not be connected through a plug-in or hardwired thermostat.

Installation Support

Royal Infrared Heating® does not provide installation services, but our team can offer guidance and help you find a local electrician.

Remove the Protective Films

Remove all protective films before use:

  • Front: Lift the film using the small sticker in the top-right corner.

  • Back: Remove the blue protective film.

Wall Mounting Only

Repulsus can be mounted vertically or horizontally on a wall. Never install it on a ceiling.

Pre-Fitted Mounting Brackets

The mounting brackets are already attached. No pre-assembly is required; secure the mirror using the four supplied screws.

Recommended Mirror Position

Mount Repulsus at a practical mirror height, facing the area where infrared warmth is needed most.

Choose a central, unobstructed wall and maintain the required distance from furniture, curtains and other objects.

Plug-In Connection

Connect the supplied 1.9-metre cable directly to a suitable grounded socket. If necessary, use a properly rated, grounded extension lead.

Do not connect Repulsus through a plug-in thermostat or modify the power cable yourself.

Hardwired Connection

For a clean, permanent installation, ask a qualified electrician to connect Repulsus to a suitable electrical supply.

Repulsus must not be connected through a hardwired thermostat. Restoring power does not automatically activate the LED or heating element.

Touch-Sensor Control

Use the built-in touch sensor to operate Repulsus. Tap the sensor to control the LED backlight and press and hold it to control the infrared heating element.

After a power interruption, use the touch sensor to reactivate the required function.

icon-infrared-towel-rails

IR Towel Rail Linteum Installation Guide

icon-infrared-towel-rails

Linteum Panel Setup

Clear fitting and setup instructions for installing your Linteum infrared towel rail heater safely and correctly

ES-high-quality-components-whiten
fv26

Website rating

4.9 Royal Infrared Heating reviews

Based on 900+ reviews

Effortless Installation for Maximum Comfort

At Royal Infrared Heating®, we combine efficient bathroom heating with straightforward installation. Linteum is designed for simple vertical wall mounting. Attach the towel rail before mounting the panel, then follow the supplied instructions. Standard plug-in installation does not normally require an electrician, while hardwired installation must be completed by a qualified professional.

Quick and Simple Wall Mounting

Installing Linteum requires four holes to be drilled into a suitable wall. Each unit includes screws, wall plugs, towel-rail fittings and a detailed drilling template. For clear, step-by-step instructions, please follow the Linteum Installation Guide below.

1. Remove the Caps

Choose the mounting bracket and remove its two plastic caps.

The upper position is recommended for larger towels.

2. Fit the Towel Rail

Insert the two aluminium caps into the selected bracket.

Hold the towel rail in position and insert the supplied screws.

3. Tighten and Check

Tighten all screws evenly until the towel rail is secure.

Confirm that the rail is aligned and stable.

4. Mounting Position

Choose a suitable wall and select vertical or horizontal mounting.

Keep the panel at least 10 cm from nearby walls or objects and approximately 30 cm above the floor. Never install the Domus on a ceiling.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-1-min

5. Mark, Drill the Holes

Attach the drilling template to the wall and mark the four mounting points.

Use ANLT for the Domus 900W or AEHK for the Domus 580W, then drill each marked hole using a suitable 8 mm bit.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-2-min

6. Install Wall the Fixings

Insert the supplied wall plugs fully into the four drilled holes.

Fit the screws securely, leaving each screw head approximately 5 mm from the wall so the panel’s mounting brackets can attach safely and remain supported.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-3-min

7. Hang the Panel

Align the pre-fitted brackets on the back of the panel with the four screw heads.

Carefully place the panel onto the screws and ensure that every mounting point is correctly engaged.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-4-min

8. Secure the Panel

Slide the panel sideways until the screws move into the locked sections of the mounting brackets.

Check that the panel is level, stable and securely attached before releasing it.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-5-min

9. Connect the Power

Connect the power cable to a suitable grounded wall socket and use the rear power switch to operate the heater.

When using a plug-in thermostat, connect the heater to the thermostat first, then plug the thermostat into the wall socket.

far-infrared-towel-heater-linteum-installation-guide-mount-heater-step-6-min

Attach the Towel Rail First

Before mounting Linteum on the wall, attach the towel rail to the preferred upper or lower position using the supplied fittings.

Make sure the rail is correctly aligned and securely tightened before continuing with the wall installation.

Recommended Heater Position

Mount Linteum vertically on the middle or lower section of a wall, at a practical height for using the towel rail.

Choose an unobstructed position facing the area where warmth is needed. Maintain the required distance from furniture, curtains and other objects.

Plug-In Connection

Connect the supplied 1.9-metre cable to a nearby grounded socket. If necessary, use a properly rated, grounded extension lead.

For plug-in thermostat control, connect Linteum to the thermostat and then connect the thermostat to the wall socket. Never modify the power cable yourself.

Hardwired Connection

For a clean, permanent installation, ask a qualified electrician to connect Linteum to a suitable electrical supply.

When using a mains-powered thermostat, Linteum connects to the thermostat, which then connects to the mains supply.

Thermostat Position

Position the thermostat in the same room, where it can measure the general air temperature accurately.

Keep it away from the panel’s direct infrared path, windows, doors, draughts and other heat sources. Follow the separate thermostat installation guide.

Recommended Heater Position

Mount Linteum vertically at a practical height for using the towel rail, facing the area where infrared warmth is needed most.

Choose an unobstructed wall and maintain the required distance from furniture, curtains and other objects.

Plug-In Connection

Connect the supplied 1.9-metre cable to a nearby grounded socket. If necessary, use a properly rated, grounded extension lead.

For plug-in thermostat control, connect Linteum to the thermostat and then connect the thermostat to the wall socket. Never modify the power cable yourself.

Hardwired Connection

For a clean, permanent installation, ask a qualified electrician to connect Linteum to a suitable electrical supply.

When using a mains-powered thermostat, Linteum connects to the thermostat, which then connects to the mains supply.

Thermostat Position

Position the thermostat in the same room, where it can measure the general air temperature accurately.

Keep it away from the panel’s direct infrared path, windows, doors, draughts and other heat sources. Follow the separate thermostat installation guide.

icon-infrared-panels

IR Panel Domus Installation Guide

icon-infrared-panels

Domus Panel Setup

Clear fitting and setup instructions for installing your Domus infrared panel heater safely and correctly

ES-high-quality-components-whiten
fv26

Website rating

4.9 Royal Infrared Heating reviews

Based on 900+ reviews

Effortless Installation for Maximum Comfort

At Royal Infrared Heating®, we prioritize not only efficient heating but also ease of installation. Our Domus Far Infrared Panels are designed to be user-friendly, allowing most customers to complete the installation without the need for a professional electrician. Whether you’re a seasoned DIY enthusiast or a first-time installer, our panels are developed with simplicity and practicality in mind.

Quick and Simple Wall Mounting

Installing a Domus panel requires only four holes to be drilled into the wall. Each unit comes complete with an installation kit, including screws, dowels, and a detailed drilling template, making the process straightforward and stress-free. To assist further, we’ve prepared a step-by-step Installation Guide, which you can view below.

1. Mounting Position

Choose a suitable wall and select vertical or horizontal mounting.

Keep the panel at least 10 cm from nearby walls or objects and approximately 30 cm above the floor. Never install the Domus on a ceiling.

2. Mark, Drill the Holes

Attach the drilling template to the wall and mark the four mounting points.

Use ANLT for the Domus 900W or AEHK for the Domus 580W, then drill each marked hole using a suitable 8 mm bit.

3. Install Wall the Fixings

Insert the supplied wall plugs fully into the four drilled holes.

Fit the screws securely, leaving each screw head approximately 5 mm from the wall so the panel’s mounting brackets can attach safely and remain supported.

4. Hang the Panel

Align the pre-fitted brackets on the back of the panel with the four screw heads.

Carefully place the panel onto the screws and ensure that every mounting point is correctly engaged.

5. Secure the Panel

Slide the panel sideways until the screws move into the locked sections of the mounting brackets.

Check that the panel is level, stable and securely attached before releasing it.

6. Connect the Power

Connect the power cable to a suitable grounded wall socket and use the rear power switch to operate the heater.

When using a plug-in thermostat, connect the heater to the thermostat first, then plug the thermostat into the wall socket.

Hardwired Installation

For a clean, cable-free finish, ask a qualified electrician to hardwire the Domus panel. It can usually be connected to a nearby outlet or junction box without installing a new electrical line.

Installation Support

Royal Infrared Heating® does not provide installation services, but our team can offer guidance and help you find a local electrician.

Remove the Protective Films

Remove all protective films before use:

  • Front: Lift from the small sticker in the top-right corner.

  • Back: Remove the blue protective film.

Wall Mounting Only

Domus can be mounted vertically or horizontally on a wall. Do not install it on a ceiling.

Pre-Fitted Mounting Brackets

The mounting brackets are already attached. No pre-assembly is required; mount the panel securely using the four supplied screws.

Recommended Heater Position

For efficient heating, mount the Domus on the middle or lower section of a wall, facing the area where people spend the most time. A central position helps distribute warmth evenly, although any suitable, unobstructed wall can be used. Maintain the required distance from furniture, curtains and other objects.

Plug-In Connection

The supplied power cable is approximately 1.9 metres long. Connect it to a nearby socket or, if necessary, use a properly rated, grounded extension lead. For plug-in thermostat control, connect the heater to the thermostat and then connect the thermostat to the wall socket. Do not cut, extend or modify the power cable yourself.

Hardwired Connection

For a clean, permanent installation, ask a qualified electrician to connect the heater to a suitable nearby electrical circuit or junction box. When using a mains-powered thermostat, the heater must be connected to the thermostat, which is then connected to the mains supply.

Thermostat Position

Follow the separate installation guide supplied with your thermostat. Position the thermostat in the same room as the heater, where it can measure the general air temperature accurately. Avoid placing it directly in the infrared heat path, beside the panel, near windows, doors, draughts or other heat sources.